Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38563550

RESUMO

OBJECTIVE: The objective was to assess the one year implant treatment outcome and patient-related outcome measures (PROMs) following maxillary sinus floor augmentation (MSFA) with autogenous bone graft (ABG) from the zygomatic buttress (control) compared with 1:1 mixture of ABG and anorganic porcine bone mineral (APBM) (Test I) or biphasic bone graft material (BBGM) (Test II). MATERIALS AND METHODS: Sixty healthy patients (34 females, 26 males) were randomly allocated to either control or test groups. Outcome measures included survival of suprastructures and implants, implant stability quotient, health status of peri-implant tissue, peri-implant marginal bone loss, frequency of complications, and PROMs using Oral Health Impact Profile-14 combined with questionnaire assessing patient perception of peri-implant soft tissue, prosthetic solution, implant function, and implant treatment outcome using visual analogue scale. Mean differences were expressed with standard deviation and 95% confidence interval. Level of significance was .05. RESULTS: All suprastructures and implants were well-functioning after one year of functional implant loading. There was no significant difference between control and test groups in any of the applied outcome measures. The implant stability significantly increased from implant placement to abutment connection within all groups (p < .001). High patient satisfaction and significant improvement in oral health-related quality of life was also reported within all groups. CONCLUSION: This study demonstrates that MSFA with composite grafts containing minimal amounts of ABG reveals comparable implant treatment outcomes as compared with ABG alone, after one year of functional implant loading. Extensive ABG harvesting in conjunction with MSFA therefore seems not to be needed.

2.
Int J Oral Maxillofac Implants ; 38(3): 607-618, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37279224

RESUMO

PURPOSE: To determine the biologic and biomechanical effects of two implant drilling protocols on the cortical bone around implants subjected to immediate loading. MATERIALS AND METHODS: A total of 48 implants were inserted into the mandibles of six sheep following one of two drilling protocols: undersized preparation (US; n = 24) and nonundersized preparation (NUS; n = 24). Immediately after implant insertion, an abutment was placed on each implant and 36 implants were subjected to 10 sessions of dynamic vertical loads (1,500 cycles, 1 Hz) of 25 N or 50 N. Insertion torque value (ITV) was recorded at implant installation. Resonance frequency analysis (RFA) was measured at implant insertion and at each loading session. Fluorochrome was administered at day 17, and the animals were euthanized after 5 weeks. The removal torque values (RTVs) were measured, and samples underwent histomorphometric, µCT (microcomputed tomography), and fluorescence image acquisition analyses. The bone volume density (BV/TV), bone-to-implant contact (BIC), bone area fraction occupancy (BAFO), and fluorochrome stained bone surface (MS) were calculated. A linear mixed model analysis was performed, and Pearson paired correlation was calculated. RESULTS: Five implants from the NUS group failed, with a mean ITV of 8.8 Ncm and an RFA value of 57. The mean ITVs for US group and NUS group were 80.5 (± 14) Ncm and 45.9 (± 25) Ncm, respectively (P < .001). No differences were noted in the RFA values from the time of implant insertion until the end of the study. No differences in RTV, BV/TV, BAFO, or MS were observed between the groups. Intense new bone formation took place in the NUS group implants that were subjected to load. CONCLUSIONS: Undersized preparation of cortical bone ensured a greater BIC compared to a nonundersized preparation. Moreover, this study demonstrated that immediate loading did not interfere with the osseointegration process, but loading induced intense new bone formation in the NUS group. It is not recommended to immediately load the implants when the clinically perceived primary stability is lower than an ITV of 10 Ncm and an RFA value of 60. Int J Oral Maxillofac Implants 2023;38:607-618. doi: 10.11607/jomi.9949.


Assuntos
Implantes Dentários , Animais , Ovinos , Microtomografia por Raio-X , Corantes Fluorescentes , Implantação Dentária Endóssea/métodos , Osseointegração , Torque
3.
Clin Oral Implants Res ; 34(3): 254-262, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36695016

RESUMO

OBJECTIVES: The aim of this study was to evaluate whether salivary contamination during placement of implants with different surface characteristics affects osseointegration in native and in augmented bone areas. MATERIALS AND METHODS: Forty eight implants with machined surface (MS) and 48 implants with moderately rough surface (RS) were tested in the calvaria of 12 sheep. At the first surgery, 64 bony critical defects were randomly created and were subsequently augmented with two materials (autogenous or bovine bone). After 5 weeks of graft healing, 8 implants were placed per sheep, in native bone and in the centre of the augmented defects. Forty eight implants were soaked with saliva before placement (contaminated group [CG]), while 48 implants were not (non-contaminated group [NCG]). Five weeks after implant placement, bone-to-implant contact (BIC) and bone material area fraction occupancy (BMAFO) were calculated histomorphometrically. RESULTS: Saliva contamination showed a significant negative effect (p = .000) on BIC, especially in augmented areas. RS showed significant positive effect on BIC, compared to MS (p = .000), while there were no significant differences for different bone conditions (p = .103). For BMAFO, the contamination showed a significantly negative affect (p = .000), while there were no significant differences for surface characteristics (p = .322) and for bone condition (p = .538). CONCLUSION: Saliva contamination during dental implant placement has a negative effect on osseointegration in augmented areas. Moderately rough surface has a possible advantage in the aspect of initial bone to implant contact. However, it seems to be advisable to avoid saliva contamination especially for implants placed in augmented bone areas.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Animais , Bovinos , Ovinos , Implantação Dentária Endóssea/métodos , Osseointegração , Crânio , Propriedades de Superfície , Titânio
4.
Clin Implant Dent Relat Res ; 24(1): 116-124, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35075765

RESUMO

BACKGROUND: The growing resistance of bacteria to antimicrobial medicines is a global issue and a direct threat to human health. Despite this, antibiotic prophylaxis is often still routinely used in dental implant surgery to prevent bacterial infection and early implant failure, despite unclear benefits. There is a lack of sufficient evidence to formulate clear clinical guidelines and therefore there is a need for well-designed, large-scale randomized controlled trials to determine the effect of antibiotic prophylaxis. PURPOSE: To compare the effect of a presurgical antibiotic regimen with an identical placebo regimen in healthy or relatively healthy patients receiving dental implants. MATERIALS AND METHODS: The 474 patients participating in the study were recruited from seven clinics in southern Sweden. We randomized the patients into a test and a placebo group; the study was conducted double-blinded. Preoperatively, the test group received 2 g of amoxicillin and the control group, identical placebo tablets. The primary outcome was implant failure; secondary outcomes were postoperative infections and adverse events. Patients were evaluated at two follow-ups: at 7-14 days and at 3-6 months. RESULTS: Postoperative evaluations of the antibiotic (n = 238) and the placebo (n = 235) groups noted implant failures (antibiotic group: six patients, 2.5% and placebo group: seven patients, 3.0%) and postoperative infections (antibiotic group: two patients, 0.8% and placebo group: five patients, 2.1%). No patient reported any adverse events. Between-group differences in implant failures and postoperative infections were nonsignificant. CONCLUSION: Antibiotic prophylaxis in conjunction with implant placement is likely of small benefit and should thus be avoided in most cases, especially given the unabated growth in antibiotic-resistant bacteria. CLINICAL TRIAL REGISTRATION NUMBER: NCT03412305.


Assuntos
Antibioticoprofilaxia , Implantes Dentários , Amoxicilina/uso terapêutico , Antibacterianos/uso terapêutico , Antibioticoprofilaxia/efeitos adversos , Implantação Dentária Endóssea/efeitos adversos , Implantes Dentários/efeitos adversos , Falha de Restauração Dentária , Humanos
5.
J Mech Behav Biomed Mater ; 125: 104928, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34736026

RESUMO

In order to determine a suitable thickness of polyetheretherketone (PEEK) for manufacturing of surgical membranes, the purpose was to evaluate how different thicknesses of PEEK influence the mechanical properties under flexure and tension. In total 20 specimens in PEEK with two different thicknesses, 0.5 mm and 1.0 mm were fabricated and tested in a three-point flexural strength test and tensile strength test (n = 5 specimens). Statistical analysis was done with non-parametric Mann-Whitney test with level of significance α = 0.05, for both material tests, respectively. The 1.0 mm-thick samples resulted in higher values in elastic limit and conventional deflection (Sc-value) in the flexural strength test compared to 0.5 mm-thick samples. In the tensile strength test, the results did not show any significant difference in elastic limit depending on the thickness evaluated. However, PEEK with thickness of 1.0 mm received significantly higher maximum value at fracture. Within the limitations of this study, PEEK with a thickness of 0.5 mm-1.0 mm shows mechanical properties that are appropriate thickness and can meet the complex demands for dimensioning of surgical membranes.


Assuntos
Materiais Biocompatíveis , Benzofenonas , Materiais Biocompatíveis/química , Polímeros
6.
Clin Oral Implants Res ; 33(1): 78-93, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34617341

RESUMO

OBJECTIVES: This randomised controlled trial compares the 3-year outcomes, that is, marginal bone-level (MBL) changes and clinical parameters, between an abutment-level (AL) and implant-level (IL) connection for implants with an internal conical connection (ICC) supporting a screw-retained fixed partial denture. MATERIAL AND METHODS: Fifty patients with 119 implants were randomly allocated to either the AL or IL group. Radiographic and clinical examinations were performed after one, two, and 3 years. A linear mixed model was used to evaluate the differences between groups. RESULTS: The MBL change was not significantly different between the groups at any point. The MBL was 0.12 ± 0.31 mm (AL) and 0.23 ± 0.26 mm (IL) after 1 year; 0.15 ± 0.34 mm (AL) and 0.17 ± 0.22 mm (IL) after 2 years; 0.18 ± 0.39 mm (AL) and 0.15 ± 0.21 mm (IL) after 3 years. The bleeding on probing was 43.44 ± 39.24% (AL) and 58.19 ± 41.20% (IL) after 1 year; 35.78 ± 39.22% (AL) and 50.43 ± 41.49% (IL) after 2 years; 51.27 ± 44.63% (AL) and 49.57 ± 37.31% (IL) after 3 years and was significantly different (p = .025) between 1 and 2 years. The probing depth showed a significant difference at each time point while the plaque was not significant between the groups. The overall technical, biological and prosthetic complication rates were 5.04%, 3.36%, and 16.00%, respectively. CONCLUSIONS: The MBL change was similar in the groups. The slight differences in the soft tissue complications between the groups are likely not of clinical relevance. An IL connection is considered to be a valid alternative to an AL set-up in ICC implants.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Parafusos Ósseos , Prótese Parcial Fixa , Humanos
7.
Int J Implant Dent ; 7(1): 99, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34595577

RESUMO

BACKGROUND: Autogenous bone graft is considered as the preferred grafting material for maxillary sinus floor augmentation (MSFA). However, harvesting of extraoral or intraoral autogenous bone graft is associated with risk of donor site morbidity and supplementary surgery. From a clinical and patient perspective, it would therefore be an advantage, if postoperative discomfort could be minimized by diminishing the need for autogenous bone graft harvesting. The objective of the present study was to test the hypothesis of no difference in patient's perception of recovery after MSFA with autogenous bone graft from the zygomatic buttress (control) compared with 1:1 mixture of autogenous bone graft and deproteinized porcine bone mineral (DPBM) (Test I) or biphasic bone graft material (BBGM) (Test II). Sixty healthy patients were randomly allocated to either control or test groups. Oral Health-related Quality of Life (OHRQoL) was evaluated by Oral Health Impact Profile-14 (OHIP-14) at enrollment. Recovery was estimated by self-administrated questionnaires and visual analog scale assessing pain, social and working isolation, physical appearance, eating and speaking ability, diet variations, sleep impairment and discomfort after 1 week and 1 month. Descriptive statistics was expressed as mean with standard deviation (SD). Correlation between OHRQoL at enrollment and recovery were assessed by linear regression. p-value below 0.05 was considered significant. RESULTS: Treatment satisfaction and willingness to undergo similar surgery were high in all groups. Average numbers of days with pain and sick leave were 3.5 (SD 3.9) and 0.5 (SD 1.2), respectively, with no significant difference between groups. Moreover, no significant difference in eating and speaking ability, physical appearance, work performance and sleep impairment were seen between groups. Mean OHIP-14 score at enrollment was 9.30 (SD 9.25) (control), 9.95 (SD 7.96) (Test I) and 8.15 (SD 9.37) (Test II), with no significant differences between groups. Impaired OHRQoL, gender or age seems not to predispose for delayed recovery or increased postoperative discomfort. CONCLUSIONS: MSFA with diminutive autogenous bone graft harvesting is associated with high patient satisfaction, limited postoperative discomfort and willingness to undergo similar surgery. Presurgical OHRQoL, gender or age seems not to be associated with impaired patient's perception of recovery.


Assuntos
Levantamento do Assoalho do Seio Maxilar , Animais , Transplante Ósseo , Humanos , Seio Maxilar , Percepção , Qualidade de Vida , Suínos
8.
J Oral Maxillofac Res ; 12(2): e3, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34377380

RESUMO

OBJECTIVES: Estimating blood loss is an important factor in several surgical procedures. The accuracy of blood loss measurements in situations where blood is mixed with saliva and saline is however uncertain. The purpose of this laboratory study was to ascertain if blood loss measurements in mixtures of blood, saline, and saliva are reliable and could be applicable in a clinical setting. MATERIAL AND METHODS: Venous blood and resting saliva were collected from six volunteers. Saliva, saline, and combinations thereof were mixed with blood to obtain different concentrations. A portable spectrophotometer was first used to measure the haemoglobin concentration in undiluted venous blood followed by measurements of the haemoglobin concentration after each dilution. To examine the strength of linear relationships, linear regression and Pearson correlations were used. RESULTS: The measurements of haemoglobin concentrations in mixtures of blood, saline, and saliva were proven to be accurate for haemoglobin measurements > 0.3 g/dl (correlation = 0.986 to 1). For haemoglobin measurements < 0.3 g/dl, a small increase in haemoglobin values were reported, which was directly associated to the saliva concentration in the solution (correlation = 0.983 to 1). This interference of saliva was significantly eliminated by diluting the samples with saline, mimicking the clinical situation. CONCLUSIONS: The results suggest that a portable spectrophotometer can be used clinically to preoperatively measure the haemoglobin value of a venous blood sample and postoperatively measure the haemoglobin value of the collected liquids, including shed blood, thereby achieving a highly accurate method of measuring blood loss during oral and maxillofacial surgery.

9.
Acta Odontol Scand ; 79(1): 59-68, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32835562

RESUMO

BACKGROUND: The aim of the study was to evaluate a potential association between individuals with different craniofacial types or other exposures, and the risk of infraposition due to continued growth/eruption of adjacent teeth in the anterior maxilla. MATERIALS AND METHODS: This is a systematic review in which primary studies as well as other systematic reviews are scrutinised. A search of PubMed (Medline), Scopus, Web of science and Health technology assessment (HTA) organisations and a complementary handsearch was carried out. Selected studies were read in full-text by several reviewers. The quality of the included primary studies was assessed using a protocol for assessment of risk of bias in exposure studies. RESULTS: The literature search resulted in 3,296 publications. Title and abstract screening yielded 25, whereof one systematic review, potential publications allocated for full-text inspection. The quality assessment resulted in a total of seven studies with a low/moderate risk of bias and four studies with a high risk of bias. CONCLUSION: In conclusion, a long-term risk for infraposition of dental implants, or ankylosed teeth, among natural teeth can be observed in some cases. The predisposing factors are still not fully understood since the current scientific evidence is very limited.


Assuntos
Implantes Dentários , Implantes Dentários/efeitos adversos , Humanos , Maxila , Erupção Dentária
10.
J Oral Implantol ; 47(2): 163-168, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32663272

RESUMO

This study aimed to evaluate the effect of surface hydrophilicity on the biomechanical aspects of osseointegration of dental implants in the tibia and femur of rabbits. Forty-eight mature female New Zealand White rabbits were included, and 96 commercially pure, Grade 4, titanium dental implants (control group), and 96 implants of same macro geometry with the hydrophilic surface (test group) were used in this study. One osteotomy was performed in each tibia and femur on both sides of the rabbit, and four implants were placed in each rabbit. Control and test groups were randomly allocated on the left and right sides. During surgery, insertion torque (ITQ) value of the complete implant placement was recorded. After healing periods of 0, 2, 4, and 8 weeks after surgery, implant stability quotient (ISQ) value, and removal torque (RTQ) values were measured. No statistical difference was observed for ITQ, for ISQ and for RTQ between the control group and test group in tibia/femur for all time periods. The effect of hydrophilic properties on moderately roughened surfaces has no impact in terms of biomechanical outcomes (ISQ values and RTQ values) after a healing period of 2 to 8 weeks in rabbit tibias /femurs.


Assuntos
Implantes Dentários , Osseointegração , Animais , Fenômenos Biomecânicos , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Feminino , Interações Hidrofóbicas e Hidrofílicas , Coelhos , Propriedades de Superfície , Tíbia/cirurgia , Titânio , Torque
11.
Oral Radiol ; 37(4): 573-584, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33270181

RESUMO

OBJECTIVES: To investigate rater agreement regarding measurements of height and width of the maxilla and mandible using cross-sectional images from CBCT examinations. Furthermore, to explore the association between vertical craniofacial height and alveolar bone morphology. METHODS: Pre-treatment CBCT scans from 450 patients referred for treatment to a private clinic for orthodontics and oral surgery in Scandinavia were available and of these, 180 were selected. Lateral head images were generated from the CBCT volumes to categorise subjects into three groups based on their craniofacial height. Cross-sectional images of the maxillary and mandibular bodies at three locations in the maxilla and mandible, respectively, were obtained and measured at one height and two width recordings by five raters. One-way analysis of variance with a Tukey post hoc test was performed. A significance level of 5% was used. RESULTS: Rater agreement was mostly excellent or good when measuring height and width of the maxilla and mandible in cross-sectional CBCT images. For height (of the alveolar bone/bodies), there were statistically significant differences between the low- and the high-angle groups for all the observers when measuring in the premolar and midline regions, both in the maxilla and in the mandible. CONCLUSION: The high agreement found ensures a reliable measurement technique and confirms the relation between craniofacial height and alveolar bone height and width.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Cabeça , Humanos , Mandíbula/diagnóstico por imagem
12.
Clin Oral Implants Res ; 32(1): 44-59, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33222296

RESUMO

OBJECTIVES: This RCT compares marginal bone level (MBL) change and the clinical parameters after a 3-year function in maxillary implant-supported fixed complete dentures (FCDs) treated with four-implants (4-I) or six-implants (6-I). MATERIAL AND METHOD: Three centres treated 56 patients with 280 implants allocated to the 4-I or 6-I group. Radiographic and clinical examinations were performed. The primary outcome was to investigate MBL change between the groups. RESULTS: Implant survival rates were 100% and 99% in the 4-I and 6-I groups, respectively. Considering the clustering effects, the MBL change was not significantly different between the groups over the 3-year follow-up. The MBL in the 4-I group was 0.30 ± 0.50 mm at baseline, 0.24 ± 0.31 mm at 1 year and 0.24 ± 0.38 mm at 3 years. In the 6-I group, MBL was 0.14 ± 0.32 mm at baseline, 0.16 ± 0.35 mm at 1 year and 0.12 ± 0.26 mm at 3 years. There was a statistically significant difference between the groups at BL and 3Y. No significant differences between the groups were reported for clinical parameters at each time point as well as in between the visits. The technical and biological complications rates were 1.6% and 6.0%, respectively. Prosthetic complications affected 25 FCDs (47.2%). CONCLUSION: Marginal bone level change revealed a stable condition in the 3-year period in the two groups. Few technical and biological complications occurred apart from the chipping/fracture of the prosthetic teeth. Four-implant is a feasible solution if the rehabilitation is oriented towards the most cost-effective treatment and towards avoiding bone augmentation procedures. Clinicians have to consider the potential required visits for prosthetic maintenance.


Assuntos
Implantes Dentários , Prótese Maxilofacial , Prótese Dentária Fixada por Implante , Prótese Total , Seguimentos , Humanos , Titânio , Resultado do Tratamento
13.
Int J Oral Maxillofac Implants ; 35(2): 386-394, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32142576

RESUMO

PURPOSE: Patients who have a vertical growth pattern are more prone to complete alveolar bone growth later and run a higher risk for inhibition of growth and infraposition after implants have been placed. Moreover, it has been suggested for the same category of patients that craniofacial height may influence the alveolar bone morphology of the anterior maxilla during growth. Hence, it is important to identify such patients early when considering implant treatment in young patients. The purpose of this study was to investigate the height and width of the alveolar bone in the anterior maxilla in subjects with different craniofacial heights to assess if there is a relation between craniofacial height and the dimensions of the alveolar bone in the anterior part of the maxilla. MATERIALS AND METHODS: Measurements on cephalograms and cone beam computed tomography (CBCT) images of the maxilla from 180 fully dentate subjects were analyzed and categorized into three angle groups based on the craniofacial height: low-, normal-, and high-angle groups. Measurements of the alveolar bone were taken interradicular, at six reference points distributed between the first premolar regions in the maxilla. The height and width of the alveolar bone were measured with a standardized technique at 3, 6, 9, and 12 mm from the top of the alveolar process. RESULTS: Significant differences were found regarding the height of the alveolar bone in all the subgroups and regarding the width in the 9- and 12-mm subgroups, and between low-/normal- and low-/high-angle groups, where the high-angle group represented the thinnest alveolar bone. A significant difference was found between male and female patients concerning all dimensions of the alveolar bone. CONCLUSION: There is a relation between craniofacial height and the dimensions of the alveolar bone in the anterior part of the maxilla. Craniofacial height is an important factor to analyze when implant treatment is considered in the maxillary anterior region. This identification can preferably be carried out early in young patients who are still growing when various treatment options can still be considered.


Assuntos
Implantes Dentários , Maxila , Processo Alveolar , Tomografia Computadorizada de Feixe Cônico , Estudos Transversais , Feminino , Humanos , Masculino
14.
J Mech Behav Biomed Mater ; 103: 103598, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32090927

RESUMO

PURPOSE: The aim of this multi-scale in silico study was to evaluate the influence of resorption cavities on the mechanical properties and load distribution in cortical bone after implant placement with two different drilling protocols. MATERIAL AND METHODS: Two different micro-scale bone structures were assessed: cortical bone models with cavities (test) and without cavities (control) were designed from µCT data. In a macro-scale model, representing a mandibular ridge, oblique load of 150 N was applied on the implant-abutment. Maximum principal stress/strain, and shear stress/strain were calculated in the macro- and micro-scale models. RESULTS: Test presented anisotropic material properties. In tests, significantly greater maximum values of Maximum principal stress/strain were calculated in micro-scale model. These values were located at the implant neck area in the macro-scale model and in the proximity of cavities in the micro-scale model respectively. Greater values of shear stress/strain were found in the test along the mandibular horizontal plane. CONCLUSIONS: Cortical bone with resorption cavities following undersized drilling showed an impaired load distribution compared with bone without cavities. Subsequently, stress/strain distribution suggests that this bone model is more prone to microdamage, thus delaying the healing process.


Assuntos
Osso Cortical , Implantes Dentários , Fenômenos Biomecânicos , Simulação por Computador , Osso Cortical/diagnóstico por imagem , Análise do Estresse Dentário , Análise de Elementos Finitos , Estresse Mecânico
15.
J Clin Med ; 8(8)2019 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-31405207

RESUMO

BACKGROUND: The intraosseous temperature during implant installation has never been evaluated in an in vivo controlled setup. The aims were to investigate the influence of a drilling protocol and implant surface on the intraosseous temperature during implant installation, to evaluate the influence of temperature increase on osseointegration and to calculate the heat distribution in cortical bone. METHODS: Forty Brånemark implants were installed into the metatarsal bone of Finnish Dorset crossbred sheep according to two different drilling protocols (undersized/non-undersized) and two surfaces (moderately rough/turned). The intraosseous temperature was recorded, and Finite Element Model (FEM) was generated to understand the thermal behavior. Non-decalcified histology was carried out after five weeks of healing. The following osseointegration parameters were calculated: Bone-to-implant contact (BIC), Bone Area Fraction Occupancy (BAFO), and Bone Area Fraction Occupancy up to 1.5 mm (BA1.5). A multiple regression model was used to identify the influencing variables on the histomorphometric parameters. RESULTS: The temperature was affected by the drilling protocol, while no influence was demonstrated by the implant surface. BIC was positively influenced by the undersized drilling protocol and rough surface, BAFO was negatively influenced by the temperature rise, and BA1.5 was negatively influenced by the undersized drilling protocol. FEM showed that the temperature at the implant interface might exceed the limit for bone necrosis. CONCLUSION: The intraosseous temperature is greatly increased by an undersized drilling protocol but not from the implant surface. The temperature increase negatively affects the bone healing in the proximity of the implant. The undersized drilling protocol for Brånemark implant systems increases the amount of bone at the interface, but it negatively impacts the bone far from the implant.

16.
Int J Oral Maxillofac Implants ; 34(2): 320-328, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30883615

RESUMO

PURPOSE: To evaluate the effect of misfit at implant-level fixed partial dentures (ILFPDs) and marginal bone support on the generation of implant cracks. MATERIALS AND METHODS: This in vitro study included a mechanical fatigue test and finite element analysis. A mechanical cycling loading test was performed using 16 experimental models, each consisting of two parallel implants subdivided into four groups based on the misfit and the supporting bone condition. The framework, firmly seated at implants, was dynamically loaded vertically with a force of 1,600/160 N and 15 Hz for 1 × 106 cycles. Optical microscope, scanning electron microscope (SEM), and computed tomography three-dimensional (CT-3D) analyses were performed to detect impairments. Finite element models, representing the setups in the mechanical fatigue test, were used to represent the fatigue life. RESULTS: None of the mechanical components presented distortion or fracture at the macroscopic level during the test. In a microscopy evaluation, the fatigue test revealed scratches visible in the inner part of the conical portion of the implants regardless of the groups. SEM and CT-3D analysis revealed one implant from the misfit/no bone loss group with a microfracture in the inner part of the conical interface. The simulated effective stress levels in the coronal body were higher in the misfit groups compared with the no misfit groups. The misfit groups presented effective stress levels, above 375 MPa, that penetrated the entire wall thickness. The no bone loss group presented an effective stress level above 375 MPa along its axial direction. In the no misfit group, the area presenting effective stress levels above 375 MPa in the conical connection was larger for the bone loss group compared with the no bone loss group. CONCLUSION: This study confirmed that implant fracture is an unlikely adverse event. A clear pattern of effective distribution greater than fatigue limit stresses could be noticed when the misfit was present. The dynamic load simulation demonstrated that the crack is more likely to occur when implants are fully supported by marginal bone compared with a bone loss scenario. Within the limitations of this study, it is speculated that marginal bone loss might follow the appearance of an undetected crack. Further research is needed to develop safe clinical protocols with regard to ILFPD.


Assuntos
Perda do Osso Alveolar/fisiopatologia , Implantes Dentários/efeitos adversos , Prótese Dentária Fixada por Implante/efeitos adversos , Prótese Parcial Fixa , Estresse Mecânico , Fenômenos Biomecânicos , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Falha de Prótese/etiologia , Ajuste de Prótese
17.
Odontology ; 107(3): 353-359, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30617638

RESUMO

The aim of this study was to evaluate the accuracy in volumetric measurements obtained on an experimental model using an intraoral scanner and a gravimetric method. Three identical partial dentate maxillary acrylic models with three fabricated alveolar defects, in anterior and posterior regions, were scanned using an intraoral scanner (20 scans/defects). The defects differed in terms of size and distance of neighbouring teeth. As references, replicas of each defect were created using a dimensional stable silicone impression material. After measuring the mass of each replica, the volume was calculated by dividing the mass of each replica by the density of the impression material. The defects had a volume, according to the gravimetric method, ranging from 40.5 to 143.7 mm3. The scans were imported to metrology software for analyses. Accuracy was determined in terms of trueness and precision. The mean trueness for all defect types was 0.168 mm3 (SD 0.691, range 2.82). There was no statistical significant difference between the mean trueness for all defects measured (p = 0.910). The mean precision for all defect types was 0.147 mm3 (SD 0.524, range 2.86). There were no statistical significant differences between the dental models in regard to mean precision (p = 0.401), however, there were statistical significant differences between defects in position 1 and 2 (p = 0.002) and 1 and 3 (p = 0.001). Based on the findings of this study, the intraoral scanner utilized in the current study presented an acceptable level of accuracy when measuring volume of defects.


Assuntos
Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Materiais para Moldagem Odontológica , Imageamento Tridimensional , Modelos Dentários
18.
Clin Implant Dent Relat Res ; 21(2): 238-246, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30690848

RESUMO

BACKGROUND: Screw-retained fixed partial dentures (FPD) have shown a lower incidence of biologic complications and an easier retrievability compared with cemented FPD. PURPOSE: To compare the marginal bone loss at conical connection implant restored with a screw retained cobalt-chrome FPD in an implant-level (IL) or an abutment-level (AL) setup. MATERIALS AND METHODS: Patients with at least two adjacent missing teeth were randomly allocated to be restored with IL or AL FPD. Periapical radiographs and clinical examination were taken at implant placement, prosthetic connection, 6 and 12 months to evaluate marginal bone loss (MBL), and soft tissue conditions. Complications were used to calculate prognostic indexes. RESULTS: Fifty patients were treated with 50 FPD supported by 119 implants. The difference of MBL between the IL and AL groups was statistically significant (P = 0.003). At 1 year, MBL was 0.086 ± 0.313 mm and 0.005 ± 0.222 mm in the IL and AL groups, respectively. The presence of BoP increased with time in IL, whereas it decreased in AL group (P < 0.001). A minor complication was encounted in one FPD. CONCLUSIONS: A low grade of MBL was present after 1 year. IL showed greater amount of MBL and soft tissue inflammation indexes than AL. In FPD, AL may be a safer procedure than IL setup in order to preserve a healthy periimplant tissue.


Assuntos
Implantes Dentários , Prótese Parcial Fixa , Perda do Osso Alveolar , Parafusos Ósseos , Cobalto , Prótese Dentária Fixada por Implante , Humanos
19.
J Oral Maxillofac Res ; 10(4): e2, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32158526

RESUMO

OBJECTIVES: The objective of the present systematic review was to test the hypothesis of no difference in implant treatment outcome after maxillary alveolar ridge expansion with split-crest technique compared with lateral ridge augmentation with autogenous bone block graft. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane Library search in combination with a hand-search of relevant journals was conducted. Human studies published in English until 8th of February, 2018 were included. RESULTS: One comparative and four noncomparative studies fulfilled the inclusion criteria. Both treatment modalities disclosed high survival rate of implants with few complications. High survival rate of prosthesis, implant stability values, limited peri-implant marginal bone loss and gain in maxillary alveolar ridge width were reported with the split-crest technique. Patient-reported outcome measure and length of patient treatment time was not assessed in any of the included studies. CONCLUSIONS: The split-crest technique seems to be useful for horizontal augmentation of maxillary alveolar deficiencies with high survival rate of prosthesis and implants. However, further long-term randomized controlled trials with larger patient sample as well as assessment of patient-reported outcome measures and patient treatment time are needed before well-defined conclusions can be provided about the two treatment modalities.

20.
Int J Oral Maxillofac Implants ; 33(5): 1057-1063, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30231092

RESUMO

PURPOSE: The purpose of this study was to examine the volumetric alterations and osseointegration properties in the augmented area of the ring technique using different types of bone graft material in sheep mandible bone. MATERIALS AND METHODS: Three different materials (columnar forms, 7-mm diameter, 3-mm height) were stabilized using dental implants with a turned surface in the mandible bone of Finnish Dorset cross-bred sheep: group A, autogenous bone; group B, bovine bone; group C, biphasic bone substitute. Animals were euthanized after 5 weeks (N = 6). Three-dimensional image data by digital oral scanner were taken at the surgery and sacrifice, and the volume alteration of the material was calculated. The bone samples were fixed in formalin and dehydrated in ethanol. Resin-embedded samples were subjected to non-decalcified ground sectioning, and histologic and histomorphometric analysis (bone and material area alteration, bone-to-implant contact [BIC]) were done. RESULTS: In three-dimensional (3D) image analysis, group A showed a statistically higher percentage of remaining materials compared with groups B and C. The histologic observation showed no new bone formations around the implants in all groups, especially at the maxillary site of the implant in the augmented area. In histomorphometric analysis, group A showed a statistically higher percentage of bone area (BA) compared with groups B and C; however, in all groups, bone-to-implant contact (BIC) showed low values, and there were no statistical differences between groups. CONCLUSION: The results of this study suggested that the autogenous bone maintained bone volume around the dental implant using the ring technique, and the impact of surface properties was of some importance; osseointegration with the turned surface in the augmented area showed low BIC values in all groups.


Assuntos
Aumento do Rebordo Alveolar/métodos , Implantação Dentária Endóssea/métodos , Implantes Dentários , Mandíbula/cirurgia , Osseointegração/fisiologia , Animais , Produtos Biológicos , Regeneração Óssea/fisiologia , Substitutos Ósseos , Bovinos , Imageamento Tridimensional , Maxila/cirurgia , Minerais , Ovinos , Propriedades de Superfície , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...